– –– –14 15Conguration RegistersThe DTS Series module contains several registers that control its configuration and operation. The register se

Page 3

– –– –16 17Writing to RegistersWriting to a volatile register is nearly instantaneous. Writing to a non-volatile register typically takes 16ms

Page 4 - Absolute Maximum Ratings

– –– –18 19DTS Series RF ChannelsChannel LP Mode DTS Mode Channel LP Mode DTS Mode0 902.271 902.971 42 914.900 N/A1 902.572 903.723 43 915.201

Page 5 - Pin Descriptions

– –– –20 21UART Data Rate - Address = 0x4E; NV Address = 0x03The UART data rate is set by the regDATARATE (addr 0x4E) register. The default UA

Page 6 - Module Description

– –– –22 23CRC Control - Address = 0x53; NV Address = 0x08The DTS Series protocol includes a Cyclic Redundancy Check on the received packets t

Page 7 - Protocol

– –– –24 25CSMA Enable - Address = 0x56; NV Address = 0x0BCarrier-Sense Multiple Access (CSMA) is a best-effort delivery system that listens t

Page 8 - The CMD Line

– –– –26 27Sleep Control - Address = 0x58; NV Address = 0x0DSetting this register to 0x01 places the module into Sleep mode and 0x02 places th

Page 9 - The UART Interface

– –– –28 29Release Number - NV Address = 0x78This register indicates the firmware release number for the module. Figure 38 translates the relea

Page 10 - Conguration Registers

– –– –30 31Helpful Application Notes from LinxIt is not the intention of this manual to address in depth many of the issues that should be con

Page 11 - Reading from Registers

– –– –32 33Pad LayoutThe pad layout diagram in Figure 44 is designed to facilitate both hand and automated assembly.Board Layout GuidelinesThe

Page 12 - 0xFF 0x02 ADDR CHAN

Table of Contents 1 Description 2 Ordering Information 2 Absolute Maximum Ratings 3 Electrical Specications 5 Pin Assignments 5 Pin Description

Page 13

– –– –34 35Microstrip DetailsA transmission line is a medium whereby RF energy is transferred from one place to another with minimal loss. Thi

Page 14

– –– –36 37Production GuidelinesThe module is housed in a hybrid SMD package that supports hand and automated assembly techniques. Since the m

Page 15

– –– –38 39General Antenna RulesThe following general rules should help in maximizing antenna performance.1. Proximity to objects such as a u

Page 16

– –– –40 41Common Antenna StylesThere are hundreds of antenna styles and variations that can be employed with Linx RF modules. Following is a

Page 17 - Typical Applications

– –– –42 43Regulatory ConsiderationsWhen working with RF, a clear distinction must be made between what is technically possible and what is le

Page 18 - Antenna Considerations

DisclaimerLinx Technologies is continually striving to improve the quality and function of its products. For this reason, we reserve the right to mak

Page 19 - Interference Considerations

– –1DescriptionThe DTS Series combines a state-of-the art low power wireless transceiver with a powerful multipoint-to-multipoint protocol control

Page 20 - Microstrip Details

– –– –2 3DTS Series Transceiver SpecificationsParameter Symbol Min. Typ. Max. Units NotesPower SupplyOperating Voltage VCC2.7

Page 21 - Time (Seconds)

– –– –4 5Figure 4: Electrical SpecificationsDTS Series Transceiver SpecificationsParameter Symbol Min. Typ. Max. Units NotesAdjacent Channel Rej

Page 22 - ANTENNA (MARCONI)

– –– –6 7Theory of OperationThe DTS Series transceiver is a low-cost, high-performance synthesized FSK transceiver. Its wideband operation giv

Page 23 - Common Antenna Styles

– –– –8 9Digital Transmission System (DTS)The DTS Series transceiver takes advantage of the DTS digital spread spectrum provision in FCC part

Page 24 - Regulatory Considerations

– –– –10 11Reset to Factory DefaultIt may be necessary to reset the non-volatile registers to their factory defaults. To reset the module, hol

Page 25

– –– –12 13The UART InterfaceThe module uses a standard UART interface for both data to be sent over the air and for configuring the module. Th